194A



High Speed Voltmeter mit HPIB - Schnittstelle,
dessen genaue Eigenschaften Sie dem englischen Text oder dem Datenblatt entnehmen können.

Hier mit einem Einschubmodul: Trigger und Echtzeitausgang

Bitte fragen Sie nach den zusätzlichen Kosten für eine rückführbare ISO Kalibrierung.


Ein Datenblatt zu diesem Artikel finden Sie hier.
Eine vergrößerte Abbildung befindet sich hier.

English translation of German description:
The Fluke model 194A High Speed Voltmeter is a high speed DC voltage sampling instrument suitable for a wide variety of applications, including the analysis of laboratory phenomenon, as weIl as the characterization of transient and periodic waveforms.
The model 194A can sample at rates up to l MHz with 2 1/2 digit, 8-bit usable resolution or up to 100 kHz with 4 1/2 digit, 16-bit resolution. Each A/D channel has 64K bytes
of memory allowing up to 65,535 samples to be stored for later analysis with one of the many model 194A mathematical functions.

Key model 194A features include:
  • Autoranging - Autoranging allows the instrument to measure a wide dynamic range of input signals.
  • Zero - A zero feature allows a baseline signal level to be subtracted from subsequent readings. The baseline can either be taken from an applied signal, or keyed in from the front panel or programmed over the IEEE-488 bus.
  • Filtering - Internal analogue filtering with selectable poles of 50kHz or 500kHz is available to reduce the effects of noise.
  • Math functions - A number of mathematical functions including average, integral, standard deviation, true RMS, peak and peak-to-peak are included with the instrument software.
  • IEEE-488 interface - A standard feature of the model 194A that allows the instrument to be controlled from a computer.
  • Real time output - This port allows instrument data to be transmitted to a computer or similar device at the sampling rate via a user-supplied interface.
  • Programmable sampling rates - The instrument can be programmed to sample data as fast as 1MHz or as slow as 1Hz.
  • Programmable number of samples - The number of samples per measurement sequence can be programmed to any value between 1 and 32,767 (16-bit resolution) or 1 and 65,535 (8-bit resolution).
  • Programmable triggering - The instrument can be triggered from the input signal, an external trigger signal, from the other channel (when the model 1944A option is installed) or over the IEEE-488 bus. Programmable triggering parameters include single or continuous modes, delay, slope and level.
  • XY mode - Allows the instrument to drive external display devices such as oscilloscopes and plotters. Internal software allows easy generation of graphs from sampled data.
  • Translator mode-Simplifies IEEE-488 programming by allowing the use of English-like syntax.
  • External sample control - Allows sample collection to be synchronized to external events.


Please ask for the additional fee for a current and traceable ISO calibration.


Please find a corresponding data sheet here.
Please find an enlarged image here.


Keithley 194A

Maße/ Dimensions : 435mm (B/W) x 105mm (H/H) x 445mm (T/D)
Gewicht/ Weight: 8,2 kg



Geprüft / Fully tested:   803,25 INKLUSIV MWST / 675,00 NETTO
Gewährleistung: 1 Jahr